lvm logging done

This commit is contained in:
brent s. 2019-12-23 14:52:00 -05:00
parent 48ab7f953f
commit c165e60d34
2 changed files with 560 additions and 395 deletions

View File

@ -1,4 +1,7 @@
import uuid
import logging
# import uuid
##
from lxml import etree
##
from . import _common
import aif.utils
@ -7,204 +10,25 @@ import aif.disk.luks as luks
import aif.disk.mdadm as mdadm


_logger = logging.getLogger(__name__)


_BlockDev = _common.BlockDev


class PV(object):
def __init__(self, pv_xml, partobj):
self.xml = pv_xml
self.id = self.xml.attrib('id')
self.source = self.xml.attrib('source')
self.device = partobj
if not isinstance(self.device, (block.Disk,
block.Partition,
luks.LUKS,
mdadm.Array)):
raise ValueError(('partobj must be of type '
'aif.disk.block.Disk, '
'aif.disk.block.Partition, '
'aif.disk.luks.LUKS, or'
'aif.disk.mdadm.Array'))
_common.addBDPlugin('lvm')
self.devpath = self.device.devpath
self.is_pooled = False
self.meta = None
self._parseMeta()

def _parseMeta(self):
# Note, the "UUID" for LVM is *not* a true UUID (RFC4122) so we don't convert it.
# https://unix.stackexchange.com/questions/173722/what-is-the-uuid-format-used-by-lvm
# TODO: parity with lvm_fallback.PV._parseMeta
# key names currently (probably) don't match and need to confirm the information's all present
meta = {}
try:
_meta = _BlockDev.lvm.pvinfo(self.devpath)
except _BlockDev.LVMError:
self.meta = None
self.is_pooled = False
return(None)
for k in dir(_meta):
if k.startswith('_'):
continue
elif k in ('copy',):
continue
v = getattr(_meta, k)
meta[k] = v
self.meta = meta
self.is_pooled = True
return(None)

def prepare(self):
try:
if not self.meta:
self._parseMeta()
if self.meta:
vg = self.meta['vg_name']
# LVM is SO. DUMB.
# If you're using LVM, seriously - just switch your model to mdadm. It lets you do things like
# remove disks live without restructuring the entire thing.
# That said, because the config references partitions/disks/arrays/etc. created *in the same config*,
# and it's all dependent on block devices defined in the thing, we can be reckless here.
# I'd like to take the time now to remind you to NOT RUN AIF-NG ON A "LIVE" MACHINE.
# At least until I can maybe find a better way to determine which LVs to reduce on multi-LV VGs
# so I can *then* use lvresize in a balanced manner, vgreduce, and pvmove/pvremove and not kill
# everything.
# TODO.
for lv in _BlockDev.lvm.lvs():
if lv.vg_name == vg:
_BlockDev.lvm.lvremove(vg, lv.lv_name)
_BlockDev.lvm.vgreduce(vg)
_BlockDev.lvm.vgremove(vg) # This *shouldn't* fail. In theory. But LVM is lel.
_BlockDev.lvm.pvremove(self.devpath)
# Or if I can get this working properly. Shame it isn't automagic.
# Seems to kill the LV by dropping a PV under it. Makes sense, but STILL. LVM IS SO DUMB.
# _BlockDev.lvm.vgdeactivate(vg)
# _BlockDev.lvm.pvremove(self.devpath)
# _BlockDev.lvm.vgreduce(vg)
# _BlockDev.lvm.vgactivate(vg)
##
self.meta = None
self.is_pooled = False
except _BlockDev.LVMError:
self.meta = None
self.is_pooled = False
opts = [_BlockDev.ExtraArg.new('--reportformat', 'json')]
# FUCK. LVM. You can't *specify* a UUID.
# u = uuid.uuid4()
# opts.append(_BlockDev.ExtraArg.new('--uuid', str(u)))
_BlockDev.lvm.pvcreate(self.devpath,
0,
0,
opts)
self._parseMeta()
return(None)


class VG(object):
def __init__(self, vg_xml):
self.xml = vg_xml
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.pe_size = self.xml.attrib.get('extentSize', 0)
if self.pe_size:
x = dict(zip(('from_bgn', 'size', 'type'),
aif.utils.convertSizeUnit(self.pe_size)))
if x['type']:
self.pe_size = aif.utils.size.convertStorage(self.pe_size,
x['type'],
target = 'B')
if not aif.utils.isPowerofTwo(self.pe_size):
raise ValueError('The PE size must be a power of two (in bytes)')
self.lvs = []
self.pvs = []
# self.tags = []
# for te in self.xml.findall('tags/tag'):
# self.tags.append(te.text)
_common.addBDPlugin('lvm')
self.devpath = '/dev/{0}'.format(self.name)
self.info = None
self.created = False

def addPV(self, pvobj):
if not isinstance(pvobj, PV):
raise ValueError('pvobj must be of type aif.disk.lvm.PV')
pvobj.prepare()
self.pvs.append(pvobj)
return(None)

def create(self):
if not self.pvs:
raise RuntimeError('Cannot create a VG with no PVs')
opts = [_BlockDev.ExtraArg.new('--reportformat', 'json')]
# FUCK. LVM. You can't *specify* a UUID.
# u = uuid.uuid4()
# opts.append(_BlockDev.ExtraArg.new('--uuid', str(u)))
# for t in self.tags:
# opts.append(_BlockDev.ExtraArg.new('--addtag', t))
_BlockDev.lvm.vgcreate(self.name,
[p.devpath for p in self.pvs],
self.pe_size,
opts)
for pv in self.pvs:
pv._parseMeta()
self.created = True
self.updateInfo()
return(None)

def createLV(self, lv_xml = None):
if not self.created:
raise RuntimeError('VG must be created before LVs can be added')
# If lv_xml is None, we loop through our own XML.
if lv_xml:
lv = LV(lv_xml, self)
lv.create()
# self.lvs.append(lv)
else:
for le in self.xml.findall('logicalVolumes/lv'):
lv = LV(le, self)
lv.create()
# self.lvs.append(lv)
self.updateInfo()
return(None)

def start(self):
_BlockDev.lvm.vgactivate(self.name)
self.updateInfo()
return(None)

def stop(self):
_BlockDev.lvm.vgdeactivate(self.name)
self.updateInfo()
return(None)

def updateInfo(self):
if not self.created:
return(None)
_info = _BlockDev.lvm.vginfo(self.name)
# TODO: parity with lvm_fallback.VG.updateInfo
# key names currently (probably) don't match and need to confirm the information's all present
info = {}
for k in dir(_info):
if k.startswith('_'):
continue
elif k in ('copy',):
continue
v = getattr(_info, k)
info[k] = v
self.info = info
return(None)


class LV(object):
def __init__(self, lv_xml, vgobj):
self.xml = lv_xml
_logger.debug('lv_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.vg = vgobj
self.qualified_name = '{0}/{1}'.format(self.vg.name, self.name)
_logger.debug('Qualified name: {0}'.format(self.qualified_name))
self.pvs = []
if not isinstance(self.vg, VG):
raise ValueError('vgobj must be of type aif.disk.lvm.VG')
_logger.debug('vgobj must be of type aif.disk.lvm.VG')
raise ValueError('Invalid vgobj type')
_common.addBDPlugin('lvm')
self.info = None
self.devpath = '/dev/{0}/{1}'.format(self.vg.name, self.name)
@ -216,10 +40,12 @@ class LV(object):
self.pvs = []
_indexed_pvs = {i.id: i for i in self.vg.pvs}
for pe in self.xml.findall('pvMember'):
_logger.debug('Found PV element: {0}'.format(etree.tostring(pe, with_tail = False).decode('utf-8')))
pv_id = pe.attrib('source')
if pv_id in _indexed_pvs.keys():
self.pvs.append(_indexed_pvs[pv_id])
if not self.pvs: # We get all in the VG instead since none were explicitly assigned
_logger.debug('No PVs explicitly designated to VG; adding all.')
self.pvs = self.vg.pvs
# Size processing. We have to do this after indexing PVs.
# If not x['type'], assume *extents*, not sectors
@ -251,7 +77,8 @@ class LV(object):

def create(self):
if not self.pvs:
raise RuntimeError('Cannot create LV with no associated LVs')
_logger.error('Cannot create LV with no associated PVs')
raise RuntimeError('Missing PVs')
opts = [_BlockDev.ExtraArg.new('--reportformat', 'json')]
# FUCK. LVM. You can't *specify* a UUID.
# u = uuid.uuid4()
@ -271,6 +98,7 @@ class LV(object):
return(None)

def start(self):
_logger.info('Activating LV {0} in VG {1}.'.format(self.name, self.vg.name))
_BlockDev.lvm.lvactivate(self.vg.name,
self.name,
True,
@ -279,6 +107,7 @@ class LV(object):
return(None)

def stop(self):
_logger.info('Deactivating LV {0} in VG {1}.'.format(self.name, self.vg.name))
_BlockDev.lvm.lvdeactivate(self.vg.name,
self.name,
None)
@ -287,6 +116,7 @@ class LV(object):

def updateInfo(self):
if not self.created:
_logger.warning('Attempted to updateInfo on an LV not created yet.')
return(None)
_info = _BlockDev.lvm.lvinfo(self.vg.name, self.name)
# TODO: parity with lvm_fallback.LV.updateInfo
@ -300,4 +130,211 @@ class LV(object):
v = getattr(_info, k)
info[k] = v
self.info = info
_logger.debug('Rendered info: {0}'.format(info))
return(None)


class PV(object):
def __init__(self, pv_xml, partobj):
self.xml = pv_xml
_logger.debug('pv_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.source = self.xml.attrib('source')
self.device = partobj
if not isinstance(self.device, (block.Disk,
block.Partition,
luks.LUKS,
mdadm.Array)):
_logger.error(('partobj must be of type '
'aif.disk.block.Disk, '
'aif.disk.block.Partition, '
'aif.disk.luks.LUKS, or'
'aif.disk.mdadm.Array.'))
raise ValueError('Invalid partobj type')
_common.addBDPlugin('lvm')
self.devpath = self.device.devpath
self.is_pooled = False
self.meta = None
self._parseMeta()

def _parseMeta(self):
# Note, the "UUID" for LVM is *not* a true UUID (RFC4122) so we don't convert it.
# https://unix.stackexchange.com/questions/173722/what-is-the-uuid-format-used-by-lvm
# TODO: parity with lvm_fallback.PV._parseMeta
# key names currently (probably) don't match and need to confirm the information's all present
meta = {}
try:
_meta = _BlockDev.lvm.pvinfo(self.devpath)
except _BlockDev.LVMError:
_logger.debug('PV device is not a PV yet.')
self.meta = None
self.is_pooled = False
return(None)
for k in dir(_meta):
if k.startswith('_'):
continue
elif k in ('copy', ):
continue
v = getattr(_meta, k)
meta[k] = v
self.meta = meta
_logger.debug('Rendered meta: {0}'.format(meta))
self.is_pooled = True
return(None)

def prepare(self):
try:
if not self.meta:
self._parseMeta()
if self.meta:
vg = self.meta['vg_name']
# LVM is SO. DUMB.
# If you're using LVM, seriously - just switch your model to mdadm. It lets you do things like
# remove disks live without restructuring the entire thing.
# That said, because the config references partitions/disks/arrays/etc. created *in the same config*,
# and it's all dependent on block devices defined in the thing, we can be reckless here.
# I'd like to take the time now to remind you to NOT RUN AIF-NG ON A "PRODUCTION"-STATE MACHINE.
# At least until I can maybe find a better way to determine which LVs to reduce on multi-LV VGs
# so I can *then* use lvresize in a balanced manner, vgreduce, and pvmove/pvremove and not kill
# everything.
# TODO.
for lv in _BlockDev.lvm.lvs():
if lv.vg_name == vg:
_logger.info('Removing LV {0} from VG {1}.'.format(lv.lv_name, vg))
_BlockDev.lvm.lvremove(vg, lv.lv_name)
_logger.debug('Reducing VG {0}.'.format(vg))
_BlockDev.lvm.vgreduce(vg)
_logger.info('Removing VG {0}.'.format(vg))
_BlockDev.lvm.vgremove(vg) # This *shouldn't* fail. In theory. But LVM is lel.
_logger.info('Removing PV {0}.'.format(self.devpath))
_BlockDev.lvm.pvremove(self.devpath)
# Or if I can get this working properly. Shame it isn't automagic.
# Seems to kill the LV by dropping a PV under it. Makes sense, but STILL. LVM IS SO DUMB.
# _BlockDev.lvm.vgdeactivate(vg)
# _BlockDev.lvm.pvremove(self.devpath)
# _BlockDev.lvm.vgreduce(vg)
# _BlockDev.lvm.vgactivate(vg)
##
self.meta = None
self.is_pooled = False
except _BlockDev.LVMError:
self.meta = None
self.is_pooled = False
opts = [_BlockDev.ExtraArg.new('--reportformat', 'json')]
# FUCK. LVM. You can't *specify* a UUID.
# u = uuid.uuid4()
# opts.append(_BlockDev.ExtraArg.new('--uuid', str(u)))
_BlockDev.lvm.pvcreate(self.devpath,
0,
0,
opts)
_logger.info('Created PV {0} with opts {1}'.format(self.devpath, opts))
self._parseMeta()
return(None)


class VG(object):
def __init__(self, vg_xml):
self.xml = vg_xml
_logger.debug('vg_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.pe_size = self.xml.attrib.get('extentSize', 0)
if self.pe_size:
x = dict(zip(('from_bgn', 'size', 'type'),
aif.utils.convertSizeUnit(self.pe_size)))
if x['type']:
self.pe_size = aif.utils.size.convertStorage(self.pe_size,
x['type'],
target = 'B')
if not aif.utils.isPowerofTwo(self.pe_size):
_logger.error('The PE size must be a power of two (in bytes).')
raise ValueError('Invalid PE value')
self.lvs = []
self.pvs = []
# self.tags = []
# for te in self.xml.findall('tags/tag'):
# self.tags.append(te.text)
_common.addBDPlugin('lvm')
self.devpath = '/dev/{0}'.format(self.name)
self.info = None
self.created = False

def addPV(self, pvobj):
if not isinstance(pvobj, PV):
_logger.error('pvobj must be of type aif.disk.lvm.PV.')
raise ValueError('Invalid pvbobj type')
pvobj.prepare()
self.pvs.append(pvobj)
return(None)

def create(self):
if not self.pvs:
_logger.error('Cannot create a VG with no PVs.')
raise RuntimeError('Missing PVs')
opts = [_BlockDev.ExtraArg.new('--reportformat', 'json')]
# FUCK. LVM. You can't *specify* a UUID.
# u = uuid.uuid4()
# opts.append(_BlockDev.ExtraArg.new('--uuid', str(u)))
# for t in self.tags:
# opts.append(_BlockDev.ExtraArg.new('--addtag', t))
_BlockDev.lvm.vgcreate(self.name,
[p.devpath for p in self.pvs],
self.pe_size,
opts)
for pv in self.pvs:
pv._parseMeta()
self.created = True
self.updateInfo()
return(None)

def createLV(self, lv_xml = None):
if not self.created:
_logger.info('Attempted to add an LV to a VG before it was created.')
raise RuntimeError('LV before VG creation')
# If lv_xml is None, we loop through our own XML.
if lv_xml:
_logger.debug('Explicit lv_xml specified: {0}'.format(etree.tostring(lv_xml,
with_tail = False).decode('utf-8')))
lv = LV(lv_xml, self)
lv.create()
# self.lvs.append(lv)
else:
for le in self.xml.findall('logicalVolumes/lv'):
_logger.debug('Found lv element: {0}'.format(etree.tostring(le, with_tail = False).decode('utf-8')))
lv = LV(le, self)
lv.create()
# self.lvs.append(lv)
self.updateInfo()
return(None)

def start(self):
_logger.info('Activating VG: {0}.'.format(self.name))
_BlockDev.lvm.vgactivate(self.name)
self.updateInfo()
return(None)

def stop(self):
_logger.info('Deactivating VG: {0}.'.format(self.name))
_BlockDev.lvm.vgdeactivate(self.name)
self.updateInfo()
return(None)

def updateInfo(self):
if not self.created:
_logger.warning('Attempted to updateInfo on a VG not created yet.')
return(None)
_info = _BlockDev.lvm.vginfo(self.name)
# TODO: parity with lvm_fallback.VG.updateInfo
# key names currently (probably) don't match and need to confirm the information's all present
info = {}
for k in dir(_info):
if k.startswith('_'):
continue
elif k in ('copy',):
continue
v = getattr(_info, k)
info[k] = v
self.info = info
_logger.debug('Rendered info: {0}'.format(info))
return(None)

View File

@ -1,214 +1,32 @@
import datetime
import json
import logging
import subprocess
##
from lxml import etree
##
import aif.utils
import aif.disk.block_fallback as block
import aif.disk.luks_fallback as luks
import aif.disk.mdadm_fallback as mdadm


class PV(object):
def __init__(self, pv_xml, partobj):
self.xml = pv_xml
self.id = self.xml.attrib('id')
self.source = self.xml.attrib('source')
self.device = partobj
if not isinstance(self.device, (block.Disk,
block.Partition,
luks.LUKS,
mdadm.Array)):
raise ValueError(('partobj must be of type '
'aif.disk.block.Disk, '
'aif.disk.block.Partition, '
'aif.disk.luks.LUKS, or'
'aif.disk.mdadm.Array'))
self.devpath = self.device.devpath
self.is_pooled = False
self.meta = None
self._parseMeta()

def _parseMeta(self):
# Note, the "UUID" for LVM is *not* a true UUID (RFC4122) so we don't convert it.
# https://unix.stackexchange.com/questions/173722/what-is-the-uuid-format-used-by-lvm
meta = {}
cmd = ['pvs',
'--binary',
'--nosuffix',
'--units', 'b',
'--options', '+pvall',
'--reportformat', 'json',
self.devpath]
_meta = subprocess.run(cmd, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
if _meta.returncode != 0:
self.meta = None
self.is_pooled = False
return(None)
_meta = json.loads(_meta.stdout.decode('utf-8'))['report'][0]['pv'][0]
for k, v in _meta.items():
# We *could* regex this but the pattern would be a little more complex than idea,
# especially for such predictable strings.
# These are ints.
if k in ('dev_size', 'pe_start', 'pv_ba_size', 'pv_ba_start', 'pv_ext_vsn', 'pv_free', 'pv_major',
'pv_mda_count', 'pv_mda_free', 'pv_mda_size', 'pv_mda_used_count', 'pv_minor', 'pv_pe_alloc_count',
'pv_pe_alloc_count', 'pv_size', 'pv_used'):
v = int(v)
# These are boolean.
elif k in ('pv_allocatable', 'pv_duplicate', 'pv_exported', 'pv_in_use', 'pv_missing'):
v = (True if int(v) == 1 else False)
# This is a list.
elif k == 'pv_tags':
v = [i.strip() for i in v.split(',') if i.strip() != '']
elif v.strip() == '':
v = None
meta[k] = v
self.meta = meta
self.is_pooled = True
return(None)

def prepare(self):
if not self.meta:
self._parseMeta()
# *Technically*, we should vgreduce before pvremove, but eff it.
cmd = ['pvremove',
'--force', '--force',
'--reportformat', 'json',
self.devpath]
subprocess.run(cmd)
cmd = ['pvcreate',
'--reportformat', 'json',
self.devpath]
subprocess.run(cmd)
self._parseMeta()
return(None)


class VG(object):
def __init__(self, vg_xml):
self.xml = vg_xml
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.pe_size = self.xml.attrib.get('extentSize', 0)
if self.pe_size:
x = dict(zip(('from_bgn', 'size', 'type'),
aif.utils.convertSizeUnit(self.pe_size)))
if x['type']:
self.pe_size = aif.utils.size.convertStorage(self.pe_size,
x['type'],
target = 'B')
if not aif.utils.isPowerofTwo(self.pe_size):
raise ValueError('The PE size must be a power of two (in bytes)')
self.lvs = []
self.pvs = []
# self.tags = []
# for te in self.xml.findall('tags/tag'):
# self.tags.append(te.text)
self.devpath = None
self.devpath = self.name
self.info = None
self.created = False

def addPV(self, pvobj):
if not isinstance(pvobj, PV):
raise ValueError('pvobj must be of type aif.disk.lvm.PV')
pvobj.prepare()
self.pvs.append(pvobj)
return(None)

def create(self):
if not self.pvs:
raise RuntimeError('Cannot create a VG with no PVs')
cmd = ['vgcreate',
'--reportformat', 'json',
'--physicalextentsize', '{0}b'.format(self.pe_size),
self.name]
for pv in self.pvs:
cmd.append(pv.devpath)
subprocess.run(cmd)
for pv in self.pvs:
pv._parseMeta()
self.created = True
self.updateInfo()
return(None)

def createLV(self, lv_xml = None):
if not self.created:
raise RuntimeError('VG must be created before LVs can be added')
# If lv_xml is None, we loop through our own XML.
if lv_xml:
lv = LV(lv_xml, self)
lv.create()
# self.lvs.append(lv)
else:
for le in self.xml.findall('logicalVolumes/lv'):
lv = LV(le, self)
lv.create()
# self.lvs.append(lv)
self.updateInfo()
return(None)

def start(self):
cmd = ['vgchange',
'--activate', 'y',
'--reportformat', 'json',
self.name]
subprocess.run(cmd)
self.updateInfo()
return(None)

def stop(self):
cmd = ['vgchange',
'--activate', 'n',
'--reportformat', 'json',
self.name]
subprocess.run(cmd)
self.updateInfo()
return(None)

def updateInfo(self):
info = {}
cmd = ['vgs',
'--binary',
'--nosuffix',
'--units', 'b',
'--options', '+vgall',
'--reportformat', 'json',
self.name]
_info = subprocess.run(cmd, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
if _info.returncode != 0:
self.info = None
self.created = False
return(None)
_info = json.loads(_info.stdout.decode('utf-8'))['report'][0]['vg'][0]
for k, v in _info.items():
# ints
if k in ('lv_count', 'max_lv', 'max_pv', 'pv_count', 'snap_count', 'vg_extent_count', 'vg_extent_size',
'vg_free', 'vg_free_count', 'vg_mda_count', 'vg_mda_free', 'vg_mda_size', 'vg_mda_used_count',
'vg_missing_pv_count', 'vg_seqno', 'vg_size'):
v = int(v)
# booleans
elif k in ('vg_clustered', 'vg_exported', 'vg_extendable', 'vg_partial', 'vg_shared'):
v = (True if int(v) == 1 else False)
# lists
elif k in ('vg_lock_args', 'vg_permissions', 'vg_tags'): # not 100% sure about vg_permissions...
v = [i.strip() for i in v.split(',') if i.strip() != '']
elif v.strip() == '':
v = None
info[k] = v
self.info = info
return(None)
_logger = logging.getLogger(__name__)


class LV(object):
def __init__(self, lv_xml, vgobj):
self.xml = lv_xml
_logger.debug('lv_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.vg = vgobj
self.qualified_name = '{0}/{1}'.format(self.vg.name, self.name)
_logger.debug('Qualified name: {0}'.format(self.qualified_name))
self.pvs = []
if not isinstance(self.vg, VG):
raise ValueError('vgobj must be of type aif.disk.lvm.VG')
_logger.debug('vgobj must be of type aif.disk.lvm.VG')
raise ValueError('Invalid vgobj type')
self.info = None
self.devpath = '/dev/{0}/{1}'.format(self.vg.name, self.name)
self.created = False
@ -219,10 +37,12 @@ class LV(object):
self.pvs = []
_indexed_pvs = {i.id: i for i in self.vg.pvs}
for pe in self.xml.findall('pvMember'):
_logger.debug('Found PV element: {0}'.format(etree.tostring(pe, with_tail = False).decode('utf-8')))
pv_id = pe.attrib('source')
if pv_id in _indexed_pvs.keys():
self.pvs.append(_indexed_pvs[pv_id])
if not self.pvs: # We get all in the VG instead since none were explicitly assigned
_logger.debug('No PVs explicitly designated to VG; adding all.')
self.pvs = self.vg.pvs
# Size processing. We have to do this after indexing PVs.
# If not x['type'], assume *extents*, not sectors
@ -254,15 +74,26 @@ class LV(object):

def create(self):
if not self.pvs:
raise RuntimeError('Cannot create LV with no associated LVs')
cmd = ['lvcreate',
'--reportformat', 'json']
_logger.error('Cannot create LV with no associated PVs')
raise RuntimeError('Missing PVs')
cmd_str = ['lvcreate',
'--reportformat', 'json']
if self.size > 0:
cmd.extend(['--size', self.size])
cmd_str.extend(['--size', self.size])
elif self.size == 0:
cmd.extend(['--extents', '100%FREE'])
cmd.extend([self.name,
self.vg.name])
cmd_str.extend(['--extents', '100%FREE'])
cmd_str.extend([self.name,
self.vg.name])
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to create LV successfully')
self.vg.lvs.append(self)
self.created = True
self.updateInfo()
@ -270,24 +101,47 @@ class LV(object):
return(None)

def start(self):
cmd = ['lvchange',
'--activate', 'y',
'--reportformat', 'json',
self.qualified_name]
subprocess.run(cmd)
_logger.info('Activating LV {0} in VG {1}.'.format(self.name, self.vg.name))
cmd_str = ['lvchange',
'--activate', 'y',
'--reportformat', 'json',
self.qualified_name]
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to activate LV successfully')
self.updateInfo()
return(None)

def stop(self):
cmd = ['lvchange',
'--activate', 'n',
'--reportformat', 'json',
self.qualified_name]
subprocess.run(cmd)
_logger.info('Deactivating LV {0} in VG {1}.'.format(self.name, self.vg.name))
cmd_str = ['lvchange',
'--activate', 'n',
'--reportformat', 'json',
self.qualified_name]
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to deactivate successfully')
self.updateInfo()
return(None)

def updateInfo(self):
if not self.created:
_logger.warning('Attempted to updateInfo on an LV not created yet.')
return(None)
info = {}
cmd = ['lvs',
'--binary',
@ -297,7 +151,14 @@ class LV(object):
'--reportformat', 'json',
self.qualified_name]
_info = subprocess.run(cmd, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(_info.args)))
if _info.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(_info.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
self.info = None
self.created = False
return(None)
@ -330,4 +191,271 @@ class LV(object):
v = None
info[k] = v
self.info = info
_logger.debug('Rendered info: {0}'.format(info))
return(None)


class PV(object):
def __init__(self, pv_xml, partobj):
self.xml = pv_xml
_logger.debug('pv_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.source = self.xml.attrib('source')
self.device = partobj
if not isinstance(self.device, (block.Disk,
block.Partition,
luks.LUKS,
mdadm.Array)):
_logger.error(('partobj must be of type '
'aif.disk.block.Disk, '
'aif.disk.block.Partition, '
'aif.disk.luks.LUKS, or'
'aif.disk.mdadm.Array.'))
raise ValueError('Invalid partobj type')
self.devpath = self.device.devpath
self.is_pooled = False
self.meta = None
self._parseMeta()

def _parseMeta(self):
# Note, the "UUID" for LVM is *not* a true UUID (RFC4122) so we don't convert it.
# https://unix.stackexchange.com/questions/173722/what-is-the-uuid-format-used-by-lvm
meta = {}
cmd = ['pvs',
'--binary',
'--nosuffix',
'--units', 'b',
'--options', '+pvall',
'--reportformat', 'json',
self.devpath]
_meta = subprocess.run(cmd, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(_meta.args)))
if _meta.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(_meta.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
self.meta = None
self.is_pooled = False
return(None)
_meta = json.loads(_meta.stdout.decode('utf-8'))['report'][0]['pv'][0]
for k, v in _meta.items():
# We *could* regex this but the pattern would be a little more complex than idea,
# especially for such predictable strings.
# These are ints.
if k in ('dev_size', 'pe_start', 'pv_ba_size', 'pv_ba_start', 'pv_ext_vsn', 'pv_free', 'pv_major',
'pv_mda_count', 'pv_mda_free', 'pv_mda_size', 'pv_mda_used_count', 'pv_minor', 'pv_pe_alloc_count',
'pv_pe_alloc_count', 'pv_size', 'pv_used'):
v = int(v)
# These are boolean.
elif k in ('pv_allocatable', 'pv_duplicate', 'pv_exported', 'pv_in_use', 'pv_missing'):
v = (True if int(v) == 1 else False)
# This is a list.
elif k == 'pv_tags':
v = [i.strip() for i in v.split(',') if i.strip() != '']
elif v.strip() == '':
v = None
meta[k] = v
self.meta = meta
self.is_pooled = True
_logger.debug('Rendered meta: {0}'.format(meta))
return(None)

def prepare(self):
if not self.meta:
self._parseMeta()
# *Technically*, we should vgreduce before pvremove, but eff it.
cmd_str = ['pvremove',
'--force', '--force',
'--reportformat', 'json',
self.devpath]
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to remove PV successfully')
cmd_str = ['pvcreate',
'--reportformat', 'json',
self.devpath]
cmd = subprocess.run(cmd_str)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to format successfully')
self._parseMeta()
return(None)


class VG(object):
def __init__(self, vg_xml):
self.xml = vg_xml
_logger.debug('vg_xml: {0}'.format(etree.tostring(self.xml, with_tail = False).decode('utf-8')))
self.id = self.xml.attrib('id')
self.name = self.xml.attrib('name')
self.pe_size = self.xml.attrib.get('extentSize', 0)
if self.pe_size:
x = dict(zip(('from_bgn', 'size', 'type'),
aif.utils.convertSizeUnit(self.pe_size)))
if x['type']:
self.pe_size = aif.utils.size.convertStorage(self.pe_size,
x['type'],
target = 'B')
if not aif.utils.isPowerofTwo(self.pe_size):
_logger.error('The PE size must be a power of two (in bytes).')
raise ValueError('Invalid PE value')
self.lvs = []
self.pvs = []
# self.tags = []
# for te in self.xml.findall('tags/tag'):
# self.tags.append(te.text)
self.devpath = self.name
self.info = None
self.created = False

def addPV(self, pvobj):
if not isinstance(pvobj, PV):
_logger.error('pvobj must be of type aif.disk.lvm.PV.')
raise ValueError('Invalid pvbobj type')
pvobj.prepare()
self.pvs.append(pvobj)
return(None)

def create(self):
if not self.pvs:
_logger.error('Cannot create a VG with no PVs.')
raise RuntimeError('Missing PVs')
cmd_str = ['vgcreate',
'--reportformat', 'json',
'--physicalextentsize', '{0}b'.format(self.pe_size),
self.name]
for pv in self.pvs:
cmd_str.append(pv.devpath)
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to create VG successfully')
for pv in self.pvs:
pv._parseMeta()
self.created = True
self.updateInfo()
return(None)

def createLV(self, lv_xml = None):
if not self.created:
_logger.info('Attempted to add an LV to a VG before it was created.')
raise RuntimeError('LV before VG creation')
# If lv_xml is None, we loop through our own XML.
if lv_xml:
_logger.debug('Explicit lv_xml specified: {0}'.format(etree.tostring(lv_xml,
with_tail = False).decode('utf-8')))
lv = LV(lv_xml, self)
lv.create()
# self.lvs.append(lv)
else:
for le in self.xml.findall('logicalVolumes/lv'):
_logger.debug('Found lv element: {0}'.format(etree.tostring(le, with_tail = False).decode('utf-8')))
lv = LV(le, self)
lv.create()
# self.lvs.append(lv)
self.updateInfo()
return(None)

def start(self):
_logger.info('Activating VG: {0}.'.format(self.name))
cmd_str = ['vgchange',
'--activate', 'y',
'--reportformat', 'json',
self.name]
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to activate VG successfully')
self.updateInfo()
return(None)

def stop(self):
_logger.info('Deactivating VG: {0}.'.format(self.name))
cmd_str = ['vgchange',
'--activate', 'n',
'--reportformat', 'json',
self.name]
cmd = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(cmd.args)))
if cmd.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(cmd.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(cmd, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
raise RuntimeError('Failed to deactivate VG successfully')
self.updateInfo()
return(None)

def updateInfo(self):
if not self.created:
_logger.warning('Attempted to updateInfo on a VG not created yet.')
return(None)
info = {}
cmd_str = ['vgs',
'--binary',
'--nosuffix',
'--units', 'b',
'--options', '+vgall',
'--reportformat', 'json',
self.name]
_info = subprocess.run(cmd_str, stdout = subprocess.PIPE, stderr = subprocess.PIPE)
_logger.info('Executed: {0}'.format(' '.join(_info.args)))
if _info.returncode != 0:
_logger.warning('Command returned non-zero status')
_logger.debug('Exit status: {0}'.format(str(_info.returncode)))
for a in ('stdout', 'stderr'):
x = getattr(_info, a)
if x:
_logger.debug('{0}: {1}'.format(a.upper(), x.decode('utf-8').strip()))
self.info = None
self.created = False
return(None)
_info = json.loads(_info.stdout.decode('utf-8'))['report'][0]['vg'][0]
for k, v in _info.items():
# ints
if k in ('lv_count', 'max_lv', 'max_pv', 'pv_count', 'snap_count', 'vg_extent_count', 'vg_extent_size',
'vg_free', 'vg_free_count', 'vg_mda_count', 'vg_mda_free', 'vg_mda_size', 'vg_mda_used_count',
'vg_missing_pv_count', 'vg_seqno', 'vg_size'):
v = int(v)
# booleans
elif k in ('vg_clustered', 'vg_exported', 'vg_extendable', 'vg_partial', 'vg_shared'):
v = (True if int(v) == 1 else False)
# lists
elif k in ('vg_lock_args', 'vg_permissions', 'vg_tags'): # not 100% sure about vg_permissions...
v = [i.strip() for i in v.split(',') if i.strip() != '']
elif v.strip() == '':
v = None
info[k] = v
self.info = info
_logger.debug('Rendered info: {0}'.format(info))